TradeIndia
voice search
Accudx Cq Triple Marker Ck-mb/ctni/yo Rapid Test Kit Pack Of 25 Tests Na
SharePDF

Accudx Cq Triple Marker Ck-mb/ctni/yo Rapid Test Kit Pack Of 25 Tests Na

Price: 33600.00 INR / Pack

(30000.00 INR + 12% GST)

Get Latest Price

MRP:

35400.00 INR / Pack

Weight :

360.00 Gram

1 Pack Contains :

1

Minimum Pack Size :

1

In Stock

In Stock

-1+

Product Specifications

ColorWhite
MaterialPlastic
ConditionNew
TechnologyOther
PortableYes
DisposableYes
Wall MountedNo
Light SourceNo
ResolutionReading
Software DetailAccuDx CQ
MeasurementOther
Data Transmission ModeWireless
Real-Time OperationYes
Operating TypeManual
Power SourceManual
BatteryCassette
LightLED
Size20 X 13.5 X6.5
Weight360 Grams (g)
UsageDetermination of CK-MB/cTnl/Myoin serum, plasma or whole blood
AttributesLatest Technology, Good Imagining Power, Sterilized, Easy To Operate, Safe to Use, Other, Higher Level of Accuracy
FOB PortEXW ABPL
Payment TermsCash on Delivery (COD), Cash Against Delivery (CAD), Cash Advance (CA), Cash in Advance (CID), Cheque
Supply Ability100000 Per Day
Delivery Time2 Days
Sample PolicyFree samples available with shipping and taxes paid by the buyer
Packaging DetailsACCUDx CQ CK-MB/cTnl/Myo kit contains:ACCUDx CQ CK-MB/CTnI/Myo test card in a sealed pouch with desiccant 25Disposable pipetWhole blood bufferSD/RFID cardUser manual
Main Export Market(s)Australia, North America, South America, Eastern Europe, Western Europe, Middle East, Africa, Central America, Asia
Main Domestic MarketAll India
CertificationsISO
Pkg Box Length20.00 cm
ReturnableNo
Unit TypePack/Packs
Mop1
Product Unit1 Pack/Packs
CurrencyINR
Stock Quantity100
Min Quantity1
Brand NameAccurex Biomedical
GSTIN12%
Max Quantity100
Pkg Box Breadth13.50 cm
Price Typefixed
MRP35400.00 INR
Packsize1
Price30000.00 INR (Approx.)
ColorWhite
Weight360.00 Gram
Shipping Rate5.00
Shipping Typeorder_percent
Pkg Box Height6.50 cm
Moq1
Minimum Ordered Packs1
Minimum Order Quantity1

Product Overview

Key Features

AccuDx Triple Marker CK-MB/cTnI/yo Fast Test Kit (Immunofluorescence Assay) is intended for in vitro quantitative determination of CK-MB/cTnl/Myoin serum, plasma or whole blood. This test is used as an aid in the clinical diagnosis, prognosis and evaluation of myocardial injury such as Acute Myocardial Infarction (AMI), Unstable Angina, Acute Myocarditis and Acute Coronary Syndrome.

Creatine kinases are dimer isozymes composed of two monomer subunits, CK-M (for skeletal muscle derived) and CK-B (for brain derived), which can form al three combinations of monomers: CK-BB, CK-MM, and CK-MB. BB is found primarily in the brain. Skeletal muscles primarily contain the MM isoform, with trace amount of MB (around 1-4% of total CK activity). Cardiac muscles also contain the MM isoform, but higher amount of MB, typicaly around 20% of total CK activity. CK-MB is a more sensitive marker of
myocardial injury than total CK activity, because it has a lower basal level and a much narrower normal range. Medical literatures commonly state that CK-MB levels are elevated in 4 to 6 hours, peak at 10 to 24 hours, and return to normal within 3 to 4 days after an acute myocardial infarction. Classically, an increase of the myocardial-specific enzyme CK-MB is considered as the hallmark of acute myocardial infarction, and increased levels are frequently interpreted by the clinician as objective evidence of myocardial cell damage. Troponin complex consists of three regulatory proteins: T, which connects the troponin complex and tropomyosin (another cardiac muscle regulatory protein); I, which prevents muscle contraction in the absence of calcium; and C, which binds calcium. Cardiac troponin 1 (MW 22.5 kDa) and the two skeletal muscle isoforms of troponin I have considerable amino acid sequence homology, but cT contains an additional N-terminal sequence and is highly specific for myocardia.
Clinical studies have demonstrated the release of cTnl into the blood stream within hours following acute myocardial infarctions (AM) or ischemic damage. Elevated levels of cTnl are detectable in blood within 4 to 6 hours after the onset of chest pain, reaching peak concentrations in approximately 8 to 28 hours, and remain elevated for 3 to 10 days following AMI. Due to the high myocardial specificity and the long duration of elevation, cTnl has become an important marker in the diagnosis and evaluation of patients
suspected of having an AMl. Myoglobin is a small monomeric protein which serves as an intracellular oxygen storage site. It is found in abundance in the muscle and can get through into the blood circulation directly when myocardial cell is damaged mildly. Therefore, myoglobin has been advocated as a sensitive marker fo early acute myocardial injury by American College of Cardiology Committee

PRINCIPLE
Mixed monoclonal antibodies against human CK-MB, cT and Myo are conjugated with fluorescence latex and another set of anti-human CK-MB/cTnI/Myo monoclonal antibodies were coated on different test lines respectively. After the sample has been applied to the test strip, the fluorescence latex-labelled anti-human CK-MB, cTnl and My monoclonal antibodies will bind with the CK-MB, cTnl and Myo in sample respectively and form marked antigen-antibody complexes. These complexes move to the test card detection zone by capillary action. Then marked antigen-anti- body complexes will be captured on different test lines by another set of
monoclonal antibodies against human CK-MB, cT or Myo respectively resulting in the accumulation of fluorescence particles on the test lines. The fluorescence intensity of each test line increases in proportion to the amount of CK-MB, cTnl or Myo in sample.
Then insert test card into ACCUDx CQ Immunofluorescence Quantitative Analyzer, the concentration of CK-MB, cT and Myo in sample will be measured and displayed on the screen. The value will be stored in ACCUDX CQ Analyzer and available for downloading.

Company Details

Accurex Biomedical Pvt. Ltd. is company that is built on its core values of honesty, perseverance, innovation and prosperity. Our brand name, Accurex is a combination of two words, Accu and Rex, wherein Accu means accurate and Rex means authoritative influence as it is derived from a Latin word meaning king. Therefore, we proudly say that we have aptly named our brand as accuracy is shown in our work and its evidence of this is our product line of amazing quality. For this reason; we are recognized as a reliable manufacturer and trader of Semi-Auto Chemistry Analyzer, Blood Glucose Monitoring System - Meter Strips, URIT 10 G Urine Reagent Strips, Automated Electrolyte Analyzer and many more. Began as a manufacturing company in the year 1984

Business Type

Exporter, Manufacturer, Service Provider, Distributor, Supplier, Trading Company, Wholesaler, Retailer, Dealer, Fabricator, Producer

Employee Count

300

Establishment

1984

Working Days

Monday To Saturday

GST NO

27AACCA3730G1Z1

Payment Mode

Cash Advance (CA)

Certification

ISO 9001:2000

Related Products

Explore Related Categories

Seller Details

GST

GST - 27AACCA3730G1Z1

4 RatingRating

Mumbai, Maharashtra

Director

Mr Abhinav Thakur

Address

212, Udyog Mandir No. 17/C, Bhagoji Keer Marg, Mahim, Mumbai, Maharashtra, 400016, India

Report incorrect details

More Product From This seller

Compare With Similar Products

Buyer Feedback

4

5

Price Or Price Range

30000.00 INR

1000 INR

Minimum Order Quantity

1 Pack/Packs

50 Number

Condition

Material

Technology

Meril Hcv Rapid Test Card

Portable

Color

White

As shown in the image

Attributes

Size

20 X 13.5 X6.5

Standard

Disposable

Usage

Determination of CK-MB/cTnl/Myoin serum, plasma or whole blood

for Hospital

Main Export Market(s)

Africa

Asia

Packaging Details

ACCUDx CQ CK-MB/cTnl/Myo kit contains: ACCUDx CQ CK-MB/CTnI/Myo test card in a sealed pouch with desiccant 25 Disposable pipet Whole blood buffer SD/RFID card User manual

Packed in a corrugated box

Sample Policy

Free samples available with shipping and taxes paid by the buyer

Contact us for information regarding our sample policy

Main Domestic Market

All India

Delhi

Payment Terms

Cash Advance (CA)

Others